Tonometer utilization, accuracy, and calibration under field conditions.
Explore this paper's citation graph
Summary
A field survey conducted in 94 ophthalmologists' offices in the immediate area assessed the accuracy of tonometers in daily use, finding that those practitioners who themselves performed the calibration had the most accurate instruments.
- Type
- article
- Published
- 1990-12-01
- Cited by
- 83
- References
- 12
- OpenAlex
- https://openalex.org/W2011337046
- Semantic Scholar
- https://api.semanticscholar.org/CorpusID:888160
Keywords
Calibration, Medicine, Optometry, Field (mathematics), Ophthalmology
References
- The measurement of intraocular pressure.
- THE INTRAOCULAR PRESSURE
- Comparison of slit-lamp applanation tonometers.
- Repeated applanation tonometry.
- Fitting bandage lenses on flattened corneas.
- Hand-held applanation tonometer.
- The Goldmann applanation tonometer.
- A noncontact applanation tonometer. Description and clinical evaluation.
- Comparison of Goldmann and Schiotz tonometry in a community.
- Comparative intraocular pressure measurements with the pneumatonograph and Goldmann tonometer.
- Glaucoma: the damage caused by pressure. XLVI Edward Jackson memorial lecture.
- CLINICAL EVALUATION OF THE DRAEGER APPLANATION TONOMETER
Cited by
- Effect of corneal thickness on intraocular pressure measurements with the pneumotonometer, Goldmann applanation tonometer, and Tono-Pen.
- Evaluierung der Reboundtonometrie (ICare) im Vergleich zum TonopenXL und dem Goldmann-Applanationstonometer
- Immediate Intraocular Pressure and Ocular Pulse Amplitude Changes in Patients with Proliferative Diabetic Retinopathy After Panretinal Photocoagulation
- A pressure versus displacement measurement system
- Comparison of Perkins, Tono-Pen and Schiøtz tonometers in paediatric patients under general anaesthesia.
- Comparative study of two central corneal thickness measurements in glaucoma patients.
- The Effect of Various Contact Lenses on Intraocular Pressure Measurement by Goldman Tonometer
- Frequency of Goldmann Applanation Tonometer Calibration Error Checks
- Comparison of ICare Tonometer with Goldmann Applanation Tonometer in Glaucoma Patients
- Validity and limitations of the Nidek NT‐4000 non‐contact tonometer: a clinical study
- Potential effects of systematic errors in intraocular pressure measurements on screening for ocular hypertension
- Self-tonometry with the Ocuton S: evaluation of accuracy in glaucoma patients.
- Open globe injuries in children: factors predictive of a poor final visual acuity
- The inter-observer reproducibility of Shafer's sign
- Effects of corneal thickness on intraocular pressure measured with three different tonometers
- The validity of a digital eyelid tonometer (TGDc‐01) and its comparison with Goldmann applanation tonometry – a pilot study
- Comparison of Rebound Tonometer, Non-Contact Tonometer, Goldmann Applanation Tonometer and the Relationship to Central Corneal Thickness
- Intraocular pressure measurements with Goldmann applanation tonometry and dynamic contour tonometry in eyes after IntraLASIK or LASEK
- Measurement of Goldmann applanation tonometer calibration error.
- An overview of home tonometry and telemetry for intraocular pressure monitoring in humans
Related papers
- Evaluation of the Efficiency of Item Calibration
- Primary calibration of measurement microphones in the world: state of art
- HIRDLS field-of-view calibration techniques and results
- A FIELD EVALUATION OF NUCLEAR GAUGE CALIBRATION METHODS PART 2: FIELD AND BLOCKS-FIELD CALIBRATIONS
- Calibration of field-mill instrument for measuring DC electric field
- System of Ophthalmology. Vol. XI. Diseases of the Lens and Vitreous; Glaucoma and Hypotony
- Asymmetry Analysis of Macular Retinal Layers for Diagnosis of Early Glaucoma in Highly Myopic Eyes
- The Relation of Central Corneal Thickness and Intraocular Pressure in a Glaucoma Screening Population Based Study in Brooklyn, NY