Intraocular pressure measurements with Goldmann applanation tonometry and dynamic contour tonometry in eyes after IntraLASIK or LASEK
Explore this paper's citation graph
Summary
The difference between preoperative and postoperative DCT measurements was minimal, so DCT may be preferable for the measurement of intraocular pressure in eyes undergoing myopic IntraLASIK or LASEK.
- Type
- article
- Published
- 2012-11-27
- Cited by
- 14
- References
- 12
- Access
- Open access
- OpenAlex
- https://openalex.org/W2011828279
- Semantic Scholar
- https://api.semanticscholar.org/CorpusID:12008519
Keywords
Medicine, Intraocular pressure, Ophthalmology, Keratomileusis, Goldmann Applanation Tonometer
References
- Postoperative changes in intraocular pressure and corneal biomechanical metrics: Laser in situ keratomileusis versus laser‐assisted subepithelial keratectomy
- Dynamic Contour Tonometry: Presentation of a New Tonometer
- Tonometer utilization, accuracy, and calibration under field conditions.
- Comparison between Pascal dynamic contour tonometer and Goldmann applanation tonometer after different types of refractive surgery
- Change in Intraocular Pressure Measurement After Myopic LASEK: A Study Evaluating Goldmann, Pascal and Applanation Resonance Tonometry
- Sources of error with use of Goldmann-type tonometers.
- Intraocular pressure measurements using dynamic contour tonometry after laser in situ keratomileusis.
- Increased corneal thickness simulating elevated intraocular pressure.
- The effect of corneal thickness on applanation tonometry.
- Clinical significance of central corneal thickness in the management of glaucoma.
- Ten-year follow-up of excimer laser surface ablation for myopia in thin corneas.
- The Ocular Hypertension Treatment Study: baseline factors that predict the onset of primary open-angle glaucoma.
Cited by
- Comparison of Intraocular Pressure before and after Laser In Situ Keratomileusis Refractive Surgery Measured with Perkins Tonometry, Noncontact Tonometry, and Transpalpebral Tonometry
- A cross-sectional study to compare intraocular pressure measurement by sequential use of Goldman applanation tonometry, dynamic contour tonometry, ocular response analyzer, and Corvis ST
- Comparison of Corneal Biomechanical Characteristics After Surface Ablation Refractive Surgery and Novel Lamellar Refractive Surgery
- Corneal Biomechanics: A Paradigm shift in Studying Corneal Pathology
- Utility of Goldmann applanation tonometry for monitoring intraocular pressure in glaucoma patients with a history of laser refractory surgery
- Changes in corneal properties and its effect on intraocular pressure measurement following phacoemulsification with intraocular lens implantation with or without trabeculectomy
- Significance of dynamic contour tonometry in evaluation of progression of glaucoma in patients with a history of laser refractive surgery
- The effect of central corneal thickness on Goldmann tonometry: a retrospective study
- Comparison of Vision Correction and Corneal Thickness at 180-Day Follow-Up After Femtosecond Laser-Assisted In-Situ Keratomileusis (FS-LASIK), Photorefractive Keratectomy (PRK), and Small Incision Lenticule Extraction (SMILE): A Study from a Single Center in Poland of 120 Patients with Myopia
- Refractive surgery in glaucoma and suspected glaucoma patients: Critical analysis of the literature and clinical recommendations
- Challenges in Glaucoma Management in High Myopia After Refractive Surgery: A Case Report
- Intraocular Pressure Changes after Laser-Assisted In-Situ Keratomileusis versus Photorefractive Keratectomy in Myopic Eyes
- Underestimation of Intraocular Pressure (IOP) After LASIK and PRK: Systematic Review and Meta-Analysis
Related papers
- Influence of Central Corneal Thickness (CCT) on Intraocular Pressure (IOP) Measured with Goldmann Applanation Tonometer (GAT) in Normal Individuals
- A Comparison of Intraocular Pressure Measurements with the XPERT Noncontact Tonometer and Goldmann Applanation Tonometry
- Comparison of Intraocular Pressure Measurements Obtained by Rebound, Noncontact, and Goldmann Applanation Tonometry in Children.
- Assessment of a new Goldmann applanation tonometer
- A history of intraocular pressure and its measurement.
- Self-measurement with Icare HOME tonometer, patients’ feasibility and acceptability
- Two-position measurement of intraocular pressure by PT100 noncontact tonometry in comparison with Goldmann tonometry
- Goldmann applanation tonometry using sterile disposable silicone tonometer shields.
- Comparison of Rebound Tonometry, Perkins Applanation Tonometry and Ocular Response Analyser in Mucopolysaccharidosis Patients
- Oculab Tono-Pen, Goldmann applanation tonometry, and pneumatic tonometry for intraocular pressure assessment in gas-filled eyes.