Potential effects of systematic errors in intraocular pressure measurements on screening for ocular hypertension
Explore this paper's citation graph
Summary
It is concluded that tonometers should be maintained and verified at intervals short enough to control systematic errors in IOP measurements to substantially less than 1 mm Hg.
- Type
- article
- Published
- 2013-02-22
- Cited by
- 5
- References
- 29
- Access
- Open access
- OpenAlex
- https://openalex.org/W1988423192
- Semantic Scholar
- https://api.semanticscholar.org/CorpusID:205140270
Keywords
Ocular hypertension, Intraocular pressure, Glaucoma, Ophthalmology, Medicine
References
- Frequency of Goldmann Applanation Tonometer Calibration Error Checks
- Does Goldmann applanation tonometry performed by community optometrists reduce referrals? A pilot study
- Fluctuation of intraocular pressure and glaucoma progression in the early manifest glaucoma trial.
- Intraocular pressure measurement and goldmann calibration. An eye opening review of practice in United Kingdom
- Individual variability in the diurnal intraocular pressure curve.
- Agreement between two Goldmann type applanation tonometers
- Tonometer utilization, accuracy, and calibration under field conditions.
- Effects of systematic errors in blood pressure measurements on the diagnosis of hypertension
- Measurement of Goldmann applanation tonometer calibration error.
- Prevalence of open-angle glaucoma in Australia. The Blue Mountains Eye Study.
- Comparison between standard Goldmann applanation prism and disposable applanation prism in tonometry
- Assessment of true intraocular pressure: the gap between theory and practical data.
- Estimating the Risk of Developing Glaucoma
- Applied regression analysis
- Goldmann applanation tonometer calibration error checks: current practice in the UK
- Calibration errors of Goldmann tonometers in a tertiary eye care centre.
- Goldmann tonometer calibration: a national survey
- The myth of clinical precision.
- The management of glaucoma and intraocular hypertension: current approaches and recent advances
- Primary Open-Angle Glaucoma
Cited by
- Evaluation of a new rebound tonometer for self-measurement of intraocular pressure
- Aktueller Stellenwert der Druckmessung: Messverfahren und Fehlerquellen
- Novel dynamic corneal response parameters in a practice use: a critical review
- Ocular Hypertension: A Review And Evidence-Based Roadmap
- Aktueller Stellenwert der Druckmessung : Messverfahren und Fehlerquellen Value of Pressure Measurements : Methods and Sources of Errors
Related papers
- Target intraocular pressure in the management of glaucoma.
- The visual field in chronic simple glaucoma and ocular hypertension; its character, progress, relationship to the level of intraocular pressure and response to treatment
- Lack of long-term drift in timolol’s effectiveness in patients with ocular hypertension: Bengstsson B,∗ Heijl A. Invest Ophthalmol Vis Sci 2001;42:2839–2842
- Lack of long-term drift in timolol's effectiveness in patients with ocular hypertension.
- Intraocular pressure measurements in a rat glaucoma model
- Levobunolol Compared to Dipivefrin in African American Patients with Open Angle Glaucoma
- The efficacy of the combination of I-moprolol and dipivefrin in reducing the intraocular pressure in primary open-angle glaucoma or in ocular hypertension
- Minimum concentration of levobunolol required to control intraocular pressure in patients with primary open-angle glaucoma or ocular hypertension.