High‐resolution MR‐imaging of the liver with T2‐weighted sequences using integrated parallel imaging: Comparison of prospective motion correction and respiratory triggering
Explore this paper's citation graph
Summary
To compare high‐resolution T2‐weigthed images of the liver with and without integrated parallel acquisition techniques (iPAT) using either breath‐hold sequences in combination with prospective acquisition motion correction (PACE) or respiratory triggering.
- Type
- article
- Published
- 2004-09-01
- Cited by
- 108
- References
- 19
- Access
- Open access
- OpenAlex
- https://openalex.org/W2040658571
- Semantic Scholar
- https://api.semanticscholar.org/CorpusID:22942851
Keywords
Image quality, Imaging phantom, Nuclear medicine, Magnetic resonance imaging, Medicine
References
- Single breath-hold T2-weighted MR imaging of the liver: value of single-shot fast spin-echo and multishot spin-echo echoplanar imaging.
- Fast T2-weighted liver MR imaging: comparison among breath-hold turbo-spin-echo, HASTE, and inversion recovery (IR) HASTE sequences
- T2-weighted MR imaging of the abdomen: fast spin-echo vs conventional spin-echo sequences.
- Partially parallel imaging with localized sensitivities (PILS)
- Motion suppression in MR imaging of the liver: comparison of respiratory-triggered and nontriggered fast spin-echo sequences.
- Fat‐suppressed T2‐weighted MRI of the liver: Comparison of respiratory‐triggered fast spin‐echo, breath‐hold single‐shot fast spin‐echo, and breath‐hold fast‐recovery fast spin‐echo sequences
- A signal-to-noise calibration procedure for NMR imaging systems.
- Liver masses: replacement of conventional T2-weighted spin-echo MR imaging with breath-hold MR imaging.
- Abdominal MR imaging: comparison of T2-weighted fast and conventional spin-echo, and contrast-enhanced fast multiplanar spoiled gradient-recalled imaging.
- A monitoring, feedback, and triggering system for reproducible breath‐hold MR imaging
- Liver: T2-weighted MR imaging with breath-hold fast-recovery optimized fast spin-echo compared with breath-hold half-Fourier and non-breath-hold respiratory-triggered fast spin-echo pulse sequences.
- Liver T2-weighted MR imaging: comparison of fast and conventional half-Fourier single-shot turbo spin-echo, breath-hold turbo spin-echo, and respiratory-triggered turbo spin-echo sequences.
- Focal hepatic lesion detection: comparison of four T2-weighted MR imaging pulse sequences.
- Improving the detectability of focal liver lesions on T2‐weighted MR images: Ultrafast breath‐hold or respiratory‐triggered thin‐section MRI?
- Motion artifact in T2‐weighted fast spin‐echo images of the liver: Effect on image contrast and reduction of artifact using respiratory triggering in normal volunteers
- The Effect of Respiration on the Contrast and Sharpness of Liver Lesions in MRI
- Generalized autocalibrating partially parallel acquisitions (GRAPPA)
- Focal hepatic lesion detection: comparison of four fat-suppressed T2-weighted MR imaging pulse sequences.
- Simultaneous acquisition of spatial harmonics (SMASH): Fast imaging with radiofrequency coil arrays
Cited by
- High-Resolution Whole-Body Magnetic Resonance Imaging Applications at 1.5 and 3 Tesla: A Comparative Study
- Vergleich von 2D- und 3D-Sequenzen für die MRCP
- Free-Breathing Echo-Planar Imaging Based Diffusion-Weighted Magnetic Resonance Imaging of the Liver With Prospective Acquisition Correction
- Image quality of T2w-TSE of the abdomen and pelvis with Cartesian or BLADE-type k-space sampling: a retrospective interindividual comparison study.
- Lien entre les pathologies rachidiennes et l’intensité de signal IRM dans le disque intervertébral
- Non‐contrast renal artery MRA using an inflow inversion recovery steady state free precession technique (Inhance): Comparison with 3D contrast‐enhanced MRA
- Patient-adapted respiratory training: Effect on navigator-triggered 3D MRCP in painful pancreatobiliary disorders.
- Neuere Entwicklungen der Leber-MRT
- Moderne Leberbildgebung mit der MRT—aktuelle Trends und Zukunft
- Non-contrast Magnetic Resonance Angiography for Evaluation of Peripheral Arterial Disease
- T2-Weighted Liver MRI Using the MultiVane Technique at 3T: Comparison with Conventional T2-Weighted MRI
- Hepatic fat assessment using advanced Magnetic Resonance Imaging.
- Black-Blood Diffusion-Weighted EPI Acquisition of the Liver with Parallel Imaging: Comparison with a Standard T2-Weighted Sequence for Detection of Focal Liver Lesions
- Diagnostic Performance and Description of Morphological Features of Focal Nodular Hyperplasia in Gd-EOB-DTPA-Enhanced Liver Magnetic Resonance Imaging: Results of a Multicenter Trial
- High-Resolution Whole-Body Magnetic Resonance Image Tumor Staging With the Use of Parallel Imaging Versus Dual-Modality Positron Emission Tomography–Computed Tomography: Experience on a 32-Channel System
- Comparison of three free-breathing T2-weighted MRI sequences in the evaluation of focal liver lesions.
- Magnetic Resonance Imaging of Renal Disease: Recent Developments and Future Applications
- Hepatic lesions: improved image quality and detection with the periodically rotated overlapping parallel lines with enhanced reconstruction technique--evaluation of SPIO-enhanced T2-weighted MR images.
- BLADE acquisition method improves T2-weighted MR images of the female pelvis compared with a standard fast spin-echo sequence.
- Image quality and focal lesion detection on T2‐weighted MR imaging of the liver: Comparison of two high‐resolution free‐breathing imaging techniques with two breath‐hold imaging techniques
Related papers
- [Evaluation of therapeutic carbon-beam attenuation in inhomogeneous layered phantoms: Comparison with the present method using a water phantom.].
- Image quality fig. evaluator used in radiography based on contrast-detail phantom
- Image quality based x-ray dose control in cardiac imaging
- Image quality assessment using the CD-DISC phantom for vascular radiology and vascular surgery.
- Reducing CT radiation dose with iterative reconstruction algorithms: the influence of scan and reconstruction parameters on image quality and CTDIvol.
- Image Quality Performance Measurement of the microPET Focus 120
- Pembuatan In-House Phantom untuk Pengukuran Image Quality dan Dosimetri Sebagai Tool Optimasi Protokol Pemeriksaan CT Scan Thorak
- Exploration of exposure dose optimization for pelvic examination in direct digital radiography with a phantom
- Impact of CT parameters on the physical quantities related to image quality for two MDCT scanners using the ACR accreditation phantom: A phantom study.
- Quantitative image quality evaluation for kV cone-beam CT-based IGRT