A signal-to-noise calibration procedure for NMR imaging systems.
Explore this paper's citation graph
Summary
A nuclear magnetic resonance (NMR) imaging system signal-to-noise calibration technique based on an NMR projection of distilled water in a cylindrical bottle is proposed, which can characterize any arrangement of rf coils in any magnetic field as signal to noise per ml times root Hz.
- Type
- article
- Published
- 1984-03-01
- Cited by
- 257
- References
- 0
- OpenAlex
- https://openalex.org/W2011312163
- Semantic Scholar
- https://api.semanticscholar.org/CorpusID:37639843
Keywords
Calibration, Resistor, SIGNAL (programming language), Noise (video), Imaging phantom
References
No references recorded for this paper.
Cited by
- Parameter optimization and calibration of 19F magnetic resonance imaging at 1.5 Tesla.
- Implementation and evaluation of a new pulse sequence for rapid acquisition of double inversion recovery images for simultaneous suppression of white matter and CSF
- Construction of a protocol for measuring blood flow by two‐dimensional phase‐contrast MRA
- Senile plaques do not induce susceptibility effects in T 2*‐weighted MR microscopic images
- 3D reconstruction of long bones utilising magnetic resonance imaging (MRI)
- Fuzzy clustering with spatial constraints for image thresholding
- Traitement et analyse d'images IRM de diffusion pour l'estimation de l'architecture locale des tissus. (Diffusion MR image analysis for the estimation of tissues local architecture)
- Développements méthodologiques et techniques pour le contrôle qualité en imagerie par résonance magnétique
- Novel MR image analysis strategies: applications in multiple sclerosis
- Coil performance evaluation based on electrodynamics : tools for hardware design and validation in magnetic resonance imaging
- Incorporation of Rician Noise in the Analysis of Biexponential Transverse Relaxation in Cartilage using a Multiple Gradient Echo Sequence at 3T and 7T
- MRI from Picture to Proton
- Bayesian Analysis of Transverse Signal Decay with Application to Human Brain
- Robust processing of diffusion weighted image data
- Signal-to-noise measurements in magnitude images from NMR phased arrays
- Human in vivo phosphate metabolite imaging with 31P NMR
- Chasing shadows: What determines DTI metrics in gray matter regions? An in vitro and in vivo study
- Noise-adaptive anisotropic diffusion filtering of MRI images reconstructed by SENSE (sensitivity encoding) method
- Progression of emphysema in a 12-month hyperpolarized 3He-MRI study: lacunarity analysis provided a more sensitive measure than standard ADC analysis.
- Improved magnetic resonance imaging detection of prostate cancer in a transgenic mouse model.
Related papers
- A Comparison of the Noise and Voltage Coefficients of Precision Metal Film and Carbon Film Resistors
- Reducing noise in photoamplifier circuits with low noise artificial resistors
- Low-frequency noise of polymer thick-film resistors: analysis of volume and contact effects
- Noise Considerations in Resistance Bridges
- Reliability Study of a High-Precision Thick Film Resistor Network
- Stochastic cooling of solids
- Review on Excess Noise Measurements of Resistors
- Excess current noise in granular resistors
- Rotating gravity gradiometer study