Clinical and Radiographic Outcomes With Minimum 2-Year Follow-up and Sub-Analysis of Navigation vs Non-Navigation for Hip Resurfacing.
Explore this paper's citation graph
Summary
Comparable improvements in patient-reported outcomes were observed in the two groups during a minimum 2-year follow-up, and navigation-assisted surgery enhances the accuracy of acetabular component positioning, with a higher likelihood of cup placement within the safe zones.
- Type
- article
- Published
- 2024-10-21
- Cited by
- 2
- References
- 19
- Access
- Open access
- OpenAlex
- https://openalex.org/W4403646968
- Semantic Scholar
- https://api.semanticscholar.org/CorpusID:273503354
Keywords
Medicine, Minimal clinically important difference, Harris Hip Score, Radiography, Body mass index
References
- Computer navigation vs conventional mechanical jig technique in hip resurfacing arthroplasty: a meta-analysis based on 7 studies.
- Femoral neck fracture after Birmingham Hip Resurfacing Arthroplasty: prevalence, time to fracture, and outcome after revision.
- Hip Resurfacing Implant Orientation Analysis: A Comparison of a Computer-Added Design Technique and Computed Tomography.
- Metal-on-Metal Hip Arthroplasty: A Review of Adverse Reactions and Patient Management
- Revision rate of Birmingham Hip Resurfacing arthroplasty: comparison of published literature and arthroplasty register data
- Our midterm results of the Birmingham hip resurfacing with and without navigation.
- The John Charnley Award: Risk Factors for Cup Malpositioning: Quality Improvement Through a Joint Registry at a Tertiary Hospital
- A safe zone for acetabular component position in metal-on-metal hip resurfacing arthroplasty: winner of the 2012 HAP PAUL award.
- Indications and results of hip resurfacing
- Comparison of Robotic-assisted and Conventional Acetabular Cup Placement in THA: A Matched-pair Controlled Study
- Causes of Revision in Young Patients Undergoing Total Hip Arthroplasty.
- Short and mid-term outcomes and functional results in metal-on-metal hip resurfacing arthroplasty at 5 years follow-up: the Spanish experience
- Hip resurfacing generates a more physiological gait than total hip replacement: A case-control study.
- Birmingham Hip Resurfacing Using a Novel Mini-navigation System: A Case Report
- Prevalence of early hip OA features on MRI in high-impact athletes. The femoroacetabular impingement and hip osteoarthritis cohort (FORCe) study
- Diagnosis and treatment of hip and knee osteoarthritis: A review
- Birmingham Hip Resurfacing for osteoarthritis — a Canadian retrospective cohort study with a minimum 10-year follow-up
- Total Hip Arthroplasty in Patients Aged 40 to 60 years old: A Population-Based Study.
- Hip Resurfacing Arthroplasty: Past, Present and Future.
Cited by
- Increased Operative Time yet Enhanced Accuracy in Computer-Assisted vs. Mechanical Hip Resurfacing Arthroplasty: An Updated Systematic Review and Meta-Analysis
- Balancing Risk and Reward in Hip Resurfacing for Developmental Dysplasia of the Hip
- 10-Year Results of Metal-on-Metal Hip Resurfacing with Computer-Assisted Navigation.
Related papers
- Temporomandibular joint: value of coronal MR images.
- MR imaging of anteromedial and posterolateral bundles of anterior cruciate ligament of knee joint
- Evaluation of MRI Orthogonal Planes in Differential Diagnosis of Non-Tumour Brain Lesions
- Temporomandibular joint: diagnostic accuracy with sagittal and coronal MR imaging.
- Identification of the relationships between sagittal plane and coronal plane curvature in guppy models.
- The relationship between minor coronal asymmetry of the spine and measures of spinal sagittal shape in adolescents without visible scoliosis
- Diagnosis of lumber posterior marginal intraosseous cartilaginous node with multislice CT
- Only 26% of Native Knees Show an Identical Coronal Functional Knee Phenotype in the Contralateral Knee
- Oblique sagittal view of the anterior cruciate ligament: Comparison of coronal vs. axial planes as localizing sequences