Possibility of Worsening Flow Diversion Effect Due to Morphological Changes of a Stented Artery With Multiple Overlapping Stents for Partially Thrombosed Vertebral Artery Aneurysms
Explore this paper's citation graph
Summary
Overlapping stents can be used for the treatment of large and giant thrombosed vertebral artery aneurysms with flow diversion effect; however, morphological changes of the stented artery requires careful attention as it may lead to an increase in the intra-aneurysmal flow, causing negative outcomes.
- Type
- article
- Published
- 2020-12-15
- Cited by
- 8
- References
- 36
- Access
- Open access
- OpenAlex
- https://openalex.org/W3112344779
- Semantic Scholar
- https://api.semanticscholar.org/CorpusID:229162878
Keywords
Medicine, Vertebral artery, Hemodynamics, Aneurysm, Blood flow
References
- A challenging entity of unruptured giant saccular aneurysms of vertebrobasilar artery.
- Panacea or problem: flow diverters in the treatment of symptomatic large or giant fusiform vertebrobasilar aneurysms.
- The hemodynamic alterations induced by the vascular angular deformation in stent-assisted coiling of bifurcation aneurysms
- High Shear Stress and Flow Velocity in Partially Occluded Aneurysms Prone to Recanalization
- Continued growth of and increased symptoms from a thrombosed giant aneurysm of the vertebral artery after complete endovascular occlusion and trapping: the role of vasa vasorum. Case report.
- Intra-Aneurysmal Thrombosis as a Possible Cause of Delayed Aneurysm Rupture after Flow-Diversion Treatment
- Aneurysm Rupture Following Treatment with Flow-Diverting Stents: Computational Hemodynamics Analysis of Treatment
- Combined Effects of Flow Diverting Strategies and Parent Artery Curvature on Aneurysmal Hemodynamics: A CFD Study
- Delayed aneurysm rupture due to residual blood flow at the inflow zone of the intracranial paraclinoid internal carotid aneurysm treated with the Pipeline embolization device: Histopathological investigation
- Intra-aneurysmal hemodynamic alterations by a self-expandable intracranial stent and flow diversion stent: high intra-aneurysmal pressure remains regardless of flow velocity reduction
- Effect of aneurysm and ICA morphology on hemodynamics before and after flow diverter treatment
- Determining the Presence of Thin-Walled Regions at High-Pressure Areas in Unruptured Cerebral Aneurysms by Using Computational Fluid Dynamics.
- Flow diverter effect of LVIS stent on cerebral aneurysm hemodynamics: a comparison with Enterprise stents and the Pipeline device
- Selection of helical braided flow diverter stents based on hemodynamic performance and mechanical properties
- Contribution of the straightening effect of the parent artery to decreased recanalization in stent-assisted coiling of large aneurysms.
- Predisposing factors for recanalization of cerebral aneurysms after endovascular embolization: a multivariate study
- Pipeline Embolization Device in Treatment of 50 Unruptured Large and Giant Aneurysms.
- Meta-analysis of treatment outcomes of posterior circulation non-saccular aneurysms by flow diverters
- Intracranial Complex Ruptured Aneurysms Coiled with Overlapping Low-Profile Visualized Intraluminal Support Stents: Another Available Option for Complex Ruptured Intracranial Aneurysms.
- Effect of Straightening the Parent Vessels in Stent-Assisted Coil Embolization for Anterior Communicating Artery Aneurysms.
Cited by
- Therapeutic dilemmas regarding giant aneurysms of the intracranial vertebral artery causing medulla oblongata compression
- Hemodynamic Comparison of Treatment Strategies for Intracranial Vertebral Artery Fusiform Aneurysms
- Progressive volume reduction and long-term aneurysmal collapse following flow diversion treatment of giant and symptomatic cerebral aneurysms
- Flow Redirection Endoluminal Device Flow Diverter Placement for Recurrent Dolichoectatic Vertebrobasilar Artery Aneurysm Treated with Multiple Low-Profile Visualized Intraluminal Support Stents: A Case Study
- Clinical and Angiographic Outcomes of Endovascular Treatment for Acute Intracranial Vertebral Artery Dissecting Aneurysms Using Double-Overlapping Stents : Low-Profile Visualized Intraluminal Support within Enterprise Stents
- A Giant Stent for Giant Cerebral Aneurysms—The Accero®-Rex-Stent
- The Great Pretender in the Sella: A Rare Doughnut-Shaped Partially Thrombosed Internal Carotid Artery Aneurysm Mimicking Pituitary Macroadenoma
Related papers
- P08 Detection of cerebral aneurysms in unenhanced CT images of patients with subarachnoid hemorrhage using the sparing aneurysm sign (SAS)
- A Case of Non-junctional Posterior Communicating Artery Aneurysm Forming Kissing Aneurysms with an IC-PC Aneurysm
- 다수의 Aneurysm에서 Rupture Aneurysm의 Location 및 Shape에 관한 연구
- Morphological and Hemodynamic Analysis of Mirror Posterior Communicating Artery Aneurysms
- Correlation between lumenal geometry changes and hemodynamics in fusiform intracranial aneurysms.
- Association of Hemodynamic Factors With Intracranial Aneurysm Formation and Rupture: Systematic Review and Meta-analysis.
- Two-Dimensional Analysis of Hemodynamic Changes in Axial and Random Pattern Flaps
- Alterations in plantar vessel blood flow in patients with mild diabetic peripheral neuropathy
- Changes in vertebral artery blood flow following normal rotation of the cervical spine.