Feasibility of Using Accelerometer Measurements to Assess Habitual Physical Activity in Rural Heart Failure Patients
Explore this paper's citation graph
Summary
The present findings suggest that an accelerometer is a feasible and reliable measure of habitual PA in rural HF patients over time.
- Type
- article
- Published
- 2017-07-14
- Cited by
- 5
- References
- 44
- Access
- Open access
- OpenAlex
- https://openalex.org/W2735077844
- Semantic Scholar
- https://api.semanticscholar.org/CorpusID:36212013
Keywords
Medicine, Accelerometer, Physical activity, Physical therapy, Reliability (semiconductor)
References
- Exergaming to increase the exercise capacity and daily physical activity in heart failure patients: a pilot study
- Reliability of the Actigraph GT3X+ Accelerometer in Adults under Free-Living Conditions
- Psychometric properties of the portuguese version of the Kansas City cardiomyopathy questionnaire in dilated cardiomyopathy with congestive heart failure.
- Decreasing sedentary behavior by 30 minutes per day reduces cardiovascular disease risk factors in rural Americans.
- Increasing exercise capacity and quality of life of patients with heart failure through Wii gaming: the rationale, design and methodology of the HF‐Wii study; a multicentre randomized controlled trial
- Feasibility of three wearable sensors for 24 hour monitoring in middle-aged women
- The feasibility and acceptability of questionnaires and accelerometry for measuring physical activity and sedentary behaviour in adults with mental illness
- Benefits of combined aerobic/resistance/inspiratory training in patients with chronic heart failure. A complete exercise model? A prospective randomised study.
- Predictors of Physical Activity in Patients With Heart Failure: A Questionnaire Study
- Calibration of the Computer Science and Applications, Inc. accelerometer.
- Lifestyle habits and mortality from all and specific causes of death: 40-year follow-up in the Italian Rural Areas of the Seven Countries Study
- Measurement reliability and agreement in psychiatry
- Exercise-based rehabilitation for heart failure
- Actigraph GT3X: Validation and Determination of Physical Activity Intensity Cut Points
- Validation and comparison of ActiGraph activity monitors.
- The Mini‐Cog: a cognitive ‘vital signs’ measure for dementia screening in multi‐lingual elderly
- Factors associated with participant compliance in studies using accelerometers.
- Detecting and monitoring depression with a two-item questionnaire (PHQ-2).
- Calibration of self-report tools for physical activity research: the Physical Activity Questionnaire (PAQ)
- Adherence of heart failure patients to exercise: barriers and possible solutions
Cited by
- Does Connected Health Technology Improve Health-Related Outcomes in Rural Cardiac Populations? Systematic Review Narrative Synthesis
- Measurement properties of device-based physical activity instruments in ambulatory adults with physical disabilities and/or chronic diseases: a scoping review
- A scoping review on advancements in noninvasive wearable technology for heart failure management
- Non-Invasive Wearable Technology to Predict Heart Failure Decompensation
- Effectiveness of Two Highly Popular Apps: a Randomized Crossover Trial to Increase Physical Activity Among Inactive Adults (Preprint)
- Increasing Physical Activity in Inactive Adults: A Randomized Crossover Trial Comparing Two Highly Popular Apps
- An exploratory analysis of 24-h movement behaviors in individuals with cancer completing a 12-week resistance exercise intervention
Related papers
- Investigation and validation of consumer device accelerometers for the assessment of whole-body vibration
- A Multi-ranged Micro Accelerometer
- Performance Evaluation of MEMS Accelerometers
- Information Compositions of the Output Signal of Accelerometers
- Design of an accelerometer in inclination monitoring of power transmission pole
- Development of 3D Accelerometer Testing System