Hip contact forces and gait patterns from routine activities.
Explore this paper's citation graph
Summary
The paper focuses on the loading of the femoral implant component but complete data are additionally stored on an associated compact disc that contains complete gait and hip contact force data as well as calculated muscle activities during walking and stair climbing and the frequencies of daily activities observed in hip patients.
- Type
- article
- Published
- 2001-07-01
- Cited by
- 2,277
- References
- 35
- OpenAlex
- https://openalex.org/W2132129082
- Semantic Scholar
- https://api.semanticscholar.org/CorpusID:21167714
Keywords
Stair climbing, Gait, Ground reaction force, Biomechanics, Contact force
References
- Is staircase walking a risk for the fixation of hip implants?
- Studies on the Anatomy and Function of Bone and Joints
- Gesammelte Abhandlungen zur Funktionellen Anatomie des Bewegungsapparates
- Telemetric force measurements across the hip after total arthroplasty.
- The effects of walking velocity and age on hip kinematics and kinetics.
- The forces in the distal femur and the knee during walking and other activities measured by telemetry.
- Internal forces and moments in the femur during walking.
- A biomechanical investigation of the human hip.
- Contact pressures in the human hip joint measured in vivo.
- Approaches to design - Force actions transmitted by joints in the human body
- Hip joint loading during walking and running, measured in two patients.
- Direct comparison of muscle force predictions using linear and nonlinear programming.
- Comparison of hip force calculations and measurements in the same patient.
- Evaluation of ischial weight-bearing orthoses, based on in-vivo hip joint force measurements.
- Musculo-skeletal loading conditions at the hip during walking and stair climbing.
- Multichannel strain gauge telemetry for orthopaedic implants.
- Four-channel telemetry system for in vivo measurement of hip joint forces.
- Telemetry of forces from proximal femoral replacements and relevance to fixation.
- Influence of muscle forces on femoral strain distribution.
- Implantable telemetry in orthopaedics
Cited by
- ETUDE EXPERIMENTALE DE LA RUPTURE OSTEOPOROTIQUE DU COL FEMORAL
- Cyclic loading of fractured cadaveric femurs after elastomer femoroplasty: an in vitro biomechanical study.
- Roentgen stereophotogrammetric analysis of the Birmingham hip resurfacing arthroplasty. A two-year study.
- Finite element contact analysis of the hip joint
- Ablauforganisation – unfallchirurgisches und anästhesiologisches Management bei Hüftfrakturen
- Design and calibration of load sensing orthopaedic implants.
- Primary stability of uncemented femoral resurfacing implants for varying interface parameters and material formulations during walking and stair climbing.
- Development and Implementation of Mathematical Modeling, Vibration and Acoustic Emission Technique to Correlate In Vivo Kinematics, Kinetics and Sound in Total Hip Arthroplasty with Different Bearing Surfaces
- Fluid load support and contact mechanics of hemiarthroplasty in the natural hip joint.
- In vitro assessment of strength, fatigue durability, and disassembly of Ti6Al4V and CoCrMo necks in modular total hip replacements.
- The seven-year wear of highly cross-linked polyethylene in total hip arthroplasty: a double-blind, randomized controlled trial using radiostereometric analysis.
- Edge loading in metal-on-metal hips: low clearance is a new risk factor
- Stress and strain analysis of the hip joint using FEM
- In vivo hip joint contact distribution and bony impingement in normal and dysplastic human hips
- The Effect of Equal Channel Angular Extrusion (ECAE) and Boron Additions on the Mechanical Properties of a Biomedical Ti-Nb-Zr-Ta (TNZT) Alloy
- Greater Trochanteric Fixation Using a Cable System for Partial Hip Arthroplasty: A Clinical and Finite Element Analysis
- A subject-specific musculoskeletal modeling framework to predict in vivo mechanics of total knee arthroplasty.
- Hip joint degeneration due to cam impingement: a finite element analysis
- Internal fixation of fragility fractures of the femoral neck
- Evaluation of stair motion contributes to new insights into hip osteoarthritis‐related motion pathomechanics
Related papers
- GROUND REACTION FORCES OF PATIENTS WITH AN OPERATIVELY TREATED RUPTURE OF THE ACL
- Determination of the vertical ground reaction forces acting upon individual limbs during healthy and clinical gait.
- DOES THE ANKLE-FOOT ORTHOSIS IMPROVE VERTICAL FORCES DURING GAIT IN CHILDREN WITH SPASTIC DIPLEGIC CEREBRAL PALSY? A RETROSPECTIVE 3-D GAIT ANALYSIS OF 19 CHILDREN
- Biomechanical kinetic consideration of the unrestrained trans-femoral prosthetic gait using energy consumption
- Changes In Gait Biomechanics Between Level And Downhill Walking Do Not Differ Between Those With Anterior Cruciate Ligament Reconstruction And Controls
- LOWER EXTREMITIES BIOMECHANICS OF REGULAR STAIR CLIMBING: SLIM VERSUS OBESE
- Effects of Toe-Out and Toe-In Gaits on Lower-Extremity Kinematics, Dynamics, and Electromyography
- Aberrant Gait Biomechanics Are Not Associated with Aberrant Landing Biomechanics in Those with ACL Reconstruction: 1327 Board #2 June 1 8
- Early signs of gait deviation in Duchenne muscular dystrophy.