Radiological evaluation of allograft reconstruction in acetabulum with Ganz reinforcement ring in revision total hip replacement
Explore this paper's citation graph
Summary
Allograft reconstruction of the acetabulum with a Ganz reinforcement ring is a useful technique for revision total hip replacement (THR).
- Type
- article
- Published
- 2010-03-01
- Cited by
- 23
- References
- 26
- OpenAlex
- https://openalex.org/W2060567922
- Semantic Scholar
- https://api.semanticscholar.org/CorpusID:207030449
Keywords
Medicine, Acetabulum, Radiological weapon, Surgery, Femoral head
References
- Bone graft for revision hip arthroplasty: biology and future applications.
- High hip center in revision arthroplasty.
- Effects of preservation procedures on the biomechanical and osteoinductive properties of rabbit bone
- Ganz reinforcement ring for reconstruction of acetabular defects in revision total hip arthroplasty.
- Impaction allografting and the Kerboull acetabular reinforcement device
- Failure of structural acetabular allografts in cementless revision hip arthroplasty.
- Treatment outcome of two-stage revision total hip arthroplasty for infected hip arthroplasty using antibiotic-impregnated cement spacer
- The expense for one implantation of a banked bone allograft from a cadaveric donor and the issues affecting current advanced medical treatment in the Japanese orthopaedic field
- Long-term results of anti-protrusion cage and massive allografts for the management of periprosthetic acetabular bone loss.
- Revision with impacted bone allografts and the Kerboull cross plate for massive bone defect of the acetabulum.
- Revision total hip arthroplasty with shelf bulk allografts. A long-term follow-up study.
- Mueller reinforcement rings in acetabular revision Outcome in 164 hips followed for 2–17 years
- Experimental study on allogenic bone grafts
- Status of Bone Allografting in Japan – Nation-Wide Survey of Bone Grafting Performed from 1995 through 1999
- Acetabular revision using acetabular roof reinforcement ring with a hook.
- Impaction grafting and acetabular reinforcement in revision hip replacement
- High rate of failure of impaction grafting in large acetabular defects.
- Midterm results (5.5-10 years) of acetabular allograft reconstruction with the acetabular reinforcement ring during total hip revision.
- The management of severe acetabular bone loss using structural allograft and acetabular reinforcement devices.
- Acetabular reconstruction in developmental dysplasia of the hip: results of the acetabular reinforcement ring with hook.
Cited by
- Acetabular Reconstruction with Reinforcement Ring and Morsellised Graft: Technique and Medium-term Result
- Options for Managing Severe Acetabular Bone Loss in Revision Hip Arthroplasty. a Systematic Review
- Contact between the acetabulum and dome of a Kerboull-type plate influences the stress on the plate and screw
- Influence of the volume of bone defect, bone grafting methods, and hook fixation on stress on the Kerboull-type plate and screw in total hip arthroplasty: three-dimensional finite element analysis
- Loosening after acetabular revision: comparison of trabecular metal and reinforcement rings. A systematic review.
- Two-Stage Revision Total Hip Arthroplasty for Periprosthetic Infections Using Antibiotic-Impregnated Cement Spacers of Various Types and Materials
- 10-Year Survival of Acetabular Reinforcement Rings/Cages for Complex Hip Arthroplasty
- Radiography versus Multidetector Computed Tomography in Assessing Graft Integration after Acetabular Reconstruction
- Revision Total Hip Arthroplasty Using an Acetabular Reinforcement Ring With a Hook: A Precise Follow-Up, at Average 11.4 Years, of a Previous Report.
- Bone Remodeling in Acetabular Reconstruction Using a Kerboull-Type Reinforcement Device and Structural Bone-Grafting in Total Hip Arthroplasty.
- Revision total hip arthroplasty - Salvage procedures using bone allografts in Japan.
- Application of acetabular reinforcement ring with hook for correction of segmental acetabular rim defects during total hip arthroplasty revision
- Revision total hip arthroplasty using the Kerboull acetabular reinforcement device for Paprosky type III defects involving the inferior margin of the acetabulum: A MINIMUM FIVE‐YEAR FOLLOW‐UP STUDY
- Long-Term Results of Acetabular Reconstruction Using Ganz Acetabular Rings.
- Burch-Schneider ring associated with morselized bone allografts, survival and clinical outcomes after acetabular revision surgery.
- Clinical and radiological outcomes of acetabular revision with the Delta Revision TT cup
- The Ganz acetabular reinforcement ring shows excellent long-term results when used as a primary implant: a retrospective analysis of two hundred and forty primary total hip arthroplasties with a minimum follow-up of twenty years
- Acetabular Revision Surgery in Major Bone Defects
- Outcome of cages in revision arthroplasty of the acetabulum: a systematic review
- Reinforcement Rings and Cages
Related papers
- Management of acetabular accident in replacement of total hip
- A radiographic review of 135 total hip Charnley arthroplasties followed between 15 and 35 years.
- REVIEW AND ANALYSIS OF REVISION OF TOTAL HIP REPLACEMENT
- Total hip replacement in congenital dislocation of the hip.
- Two Cases needed Revision Surgery after Replacement of Femoral Head Prosthesis
- Open Reduction and Internal Fixation of Acetabular: Fractures Heterotopic Ossification and Other Complications of Treatment