High long-term loosening rate of conical screw cups
Explore this paper's citation graph
Summary
In spite of extraordinarily high primary implant stability, secondary osseointegration of this cup often fails and the annual migration rate represents a valid parameter for prediction of implant survival.
- Type
- article
- Published
- 2006-01-01
- Cited by
- 8
- References
- 38
- Access
- Open access
- OpenAlex
- https://openalex.org/W2024987287
- Semantic Scholar
- https://api.semanticscholar.org/CorpusID:30799503
Keywords
Medicine, Implant, Osseointegration, Radiography, Survival rate
References
- Hip replacement with a threaded acetabular cup. A follow-up study.
- The cementless PM hip arthroplasty. Four-to-seven-year results.
- Loosening of threaded acetabular components. Radiographic manifestations.
- Measurement accuracy in acetabular cup migration. A comparison of four radiologic methods versus roentgen stereophotogrammetric analysis.
- Radiographic assessment of cup migration and wear after hip replacement.
- Special problems of cementless fixation of total hip-joint endoprostheses with reference to the PM type
- The madreporic cementless total hip arthroplasty. New experimental data and a seven-year clinical follow-up study.
- Migration of the uncemented Harris-Galante acetabular cup: results of the einbildroentgenanalyse (EBRA) method.
- Cementless Lord total hip arthroplasty: Cup loosening common after minimum 10-year follow-up of 103 hips
- Acetabular reconstruction with a threaded prosthesis for failed total hip arthroplasty.
- More failures of uncemented acetabular screw-rings than of cemented polyethylene cups in total hip arthroplasties
- Alumina-on-Alumina Total Hip Prostheses in Patients 40 Years of Age or Younger
- Threaded cup acetabuloplasty. Early clinical experience.
- Radiographic loosening of cementless threaded acetabular cups. No additional diagnostic value of arthrography in 30 patients.
- [Radiologic changes of the bones following cement-free implantation of hip joint prosthesis in inflammatory rheumatic diseases].
- Radiostereometry of hip prostheses. Review of methodology and clinical results.
- [Medium-term results using the cement-free link endoprosthesis. Ribbed shaft V socket].
- Comparison of the results of cemented, porous-ingrowth, and threaded acetabular cup fixation. A meta-analysis of the orthopaedic literature.
- Comparison of in vivo cementless acetabular fixation.
- [Clinical results using the PM type of hip endoprosthesis].
Cited by
- Estudio a largo plazo (más de 10 años de evolución), de las complicaciones de las artroplastias trapecio-metacarpianas de tipo ARPE®
- Mechanical Compatability of Nanostructured Titanium with Human Bone
- Ten-year long-term results of total joint arthroplasties with ARPE® implant in the treatment of trapeziometacarpal osteoarthritis
- Wrist arthroplasty: where do we stand today? A review of historic and contemporary designs.
- Surrogate markers of long-term outcome in primary total hip arthroplasty
- ASEPTIC LOOSENING OF THE ACETABULAR COMPONENT IN CEMENTLESS HIP ARTHROPLASTY
- Factors That Influence Bone-Ingrowth Fixation of Press-Fit Acetabular Cups.
- Versagensursachen primärer Implantationen
Related papers
- Influence of implant microstructure on the osseointegration of immediate implants placed in periodontally infected sites. A histomorphometric study in dogs.
- The effect of clinical factors on implant osseointegration formation.
- Role of BMP-7 on biological parameters osseointegration of dental implants: Preliminary results of a preclinical study
- Effect of 50 to 60°C Heating on Osseointegration of Dental Implants in Dense Bone: An In Vivo Histological Study
- Evaluation of peri-implant tissues around single implant supporting single fixed crown: clinical considerations.
- Retrospective multicenter analysis of 3i endosseous dental implants placed over a five-year period.
- Retrospective Study of GS II Implant(Osstem) with an Internal Connection with Microthreads
- Immediate placement of implants into extraction sockets: implant survival.
- Immediate implant placement in the esthetic zone utilizing the "root-membrane" technique: clinical results up to 5 years postloading.
- Implant Survival and Radiographic Analysis of Proximal Bone Levels Surrounding a Contemporary Dental Implant