Mid-To-Long Term follow-up of Transcend Metal-On-Metal versus Interseal Metal-On-Polyethylene Bearings in Total Hip Arthroplasty
Explore this paper's citation graph
Summary
There were no significant differences between the Transcend and Interseal groups for mode of failure and survivorship, which is notable considering the younger and more active Transcend group, however, the transcend group showed significantly better clinical scores, which may have been a result of the selection methods.
- Type
- article
- Published
- 2011-09-01
- Cited by
- 3
- References
- 31
- OpenAlex
- https://openalex.org/W2014362341
- Semantic Scholar
- https://api.semanticscholar.org/CorpusID:7019029
Keywords
Osteolysis, Medicine, Survivorship curve, Total hip arthroplasty, Bearing surface
References
- The Swedish Total Hip Replacement Register
- Inflammatory pseudotumor associated with femoral nerve palsy following metal-on-metal resurfacing of the hip. A case report.
- Total hip arthroplasty.
- Total Hip Arthroplasty with Use of the Metasul Metal-on-Metal Articulation: Four to Seven-Year Results*
- The long-term results of low-friction arthroplasty of the hip performed as a primary intervention.
- Survivorship of total hip replacements.
- Development of an extremely wear‐resistant ultra high molecular weight polythylene for total hip replacements
- Long-duration metal-on-metal total hip arthroplasties with low wear of the articulating surfaces.
- No superiority of cemented metal-on-metal over metal-on-polyethylene THA in a randomized controlled trial at 10-year follow-up.
- Cementless porous-coated sockets without holes implanted with pure press-fit technique.
- In vivo wear of three types of metal on metal hip prostheses during two decades of use.
- Metal-on-metal versus metal-on-polyethylene bearings in total hip arthroplasty: a matched case-control study.
- Survivorship and retrieval analysis of Sikomet metal-on-metal total hip replacements at a mean of seven years.
- Patients' expectations and satisfaction with total hip arthroplasty.
- Experience With the Metasul Total Hip Bearing System
- An unusual lymphocytic perivascular infiltration in tissues around contemporary metal-on-metal joint replacements.
- Metal-on-metal bearings in cementless primary total hip arthroplasty.
- The Finnish Arthroplasty Register: Report of the hip register
- Large versus small femoral heads in metal-on-metal total hip arthroplasty.
- Metal on Metal Bearings in Hip Arthroplasty
Cited by
- Computer navigation vs conventional mechanical jig technique in hip resurfacing arthroplasty: a meta-analysis based on 7 studies.
- Metallkonzentrationen bei Patienten mit Metall-Metall-Gleitpaarungs-Prothese
- How Have Alternative Bearings and Modularity Affected Revision Rates in Total Hip Arthroplasty?
Related papers
- Midterm results of 506 solid trispiked reflection cementless acetabular components for primary total hip arthroplasty.
- Characteristics of Hylamer polyethylene particles isolated from peri-prosthetic tissues of failed cemented total hip arthroplasties.
- Wear Performance Improved with Highly Cross-Linked Polyethylene Acetabular Liners
- Highly cross-linked polyethylene: the debate is over--in opposition.
- Long-Term Results of Total Hip Arthroplasty with 28 millimeter Cobalt-Chromium Femoral Heads on Highly Cross-linked Polyethylene in Patients 50 years and Less
- Metal-on-metal total hip joint replacement: a minimum follow-up of five years.
- Metal-on-Metal Total Hip Joint Replacement: A Minimum Follow-Up of Five Years