Single Arc Volumetric Modulated Arc Therapy of head and neck cancer.
Explore this paper's citation graph
Summary
The VMAT algorithm in Pinnacle generated single arc VMAT plans with equivalent or better target coverage and sparing of OARs compared to IMRT, while both delivery time and MUs were decreased.
- Type
- article
- Published
- 2010-05-01
- Cited by
- 202
- References
- 25
- OpenAlex
- https://openalex.org/W2012354979
- Semantic Scholar
- https://api.semanticscholar.org/CorpusID:912458
Keywords
Pinnacle, Medicine, Nuclear medicine, Head and neck, Radiation therapy
References
- Is a single arc sufficient in volumetric-modulated arc therapy (VMAT) for complex-shaped target volumes?
- SU-FF-T-123: Comparison of Elekta VMAT with Tomotherapy: Plan Quality, Delivery Efficiency and Accuracy
- Rapid delivery of stereotactic radiotherapy for peripheral lung tumors using volumetric intensity-modulated arcs.
- Volumetric-modulated arc radiotherapy for carcinomas of the anal canal: A treatment planning comparison with fixed field IMRT.
- CT-based delineation of lymph node levels and related CTVs in the node-negative neck: DAHANCA, EORTC, GORTEC, NCIC,RTOG consensus guidelines.
- Development and evaluation of an efficient approach to volumetric arc therapy planning.
- Intensity-modulated arc therapy with dynamic multileaf collimation: an alternative to tomotherapy.
- A randomized double-blind phase III study of nimorazole as a hypoxic radiosensitizer of primary radiotherapy in supraglottic larynx and pharynx carcinoma. Results of the Danish Head and Neck Cancer Study (DAHANCA) Protocol 5-85.
- A treatment planning study comparing volumetric arc modulation with RapidArc and fixed field IMRT for cervix uteri radiotherapy.
- SU‐FF‐T‐126: Initial Experience with Philips SmartArc On An Elekta Linac
- Evaluation of the Delta4 phantom for IMRT and VMAT verification
- The physical basis of IMRT and inverse planning.
- Commissioning of volumetric modulated arc therapy (VMAT).
- Intensity modulation with photons for benign intracranial tumours: a planning comparison of volumetric single arc, helical arc and fixed gantry techniques.
- Daily image guidance with cone-beam computed tomography for head-and-neck cancer intensity-modulated radiotherapy: a prospective study.
- Quality assurance of volumetric modulated arc therapy using Elekta Synergy
- Volumetric modulated arc therapy: IMRT in a single gantry arc.
- Volumetric modulated arc radiotherapy for carcinomas of the oro-pharynx, hypo-pharynx and larynx: a treatment planning comparison with fixed field IMRT.
- Evaluation of image-guidance protocols in the treatment of head and neck cancers.
- Dosimetric verification of RapidArc treatment delivery
Cited by
- Volumetric modulated arc therapy with simultaneous integrated boost for locally advanced rectal cancer.
- 3D-Conformal RT, Fixed-Field IMRT and RapidArc, Which One is Better for Esophageal Carcinoma Treated with Elective Nodal Irradiation
- Volumetric Modulated Arc Therapy vs. c-IMRT for the Treatment of Upper Thoracic Esophageal Cancer
- Impact of Gantry Rotation Time on Plan Quality and Dosimetric Verification – Volumetric Modulated Arc Therapy (VMAT) vs. Intensity Modulated Radiotherapy (IMRT)
- Clinical and dosimetric evaluation of RapidArc versus standard sliding window IMRT in the treatment of head and neck cancer
- Effect of Photon-Beam Energy on VMAT and IMRT Treatment Plan Quality and Dosimetric Accuracy for Advanced Prostate Cancer
- Carotid-Sparing TomoHelical 3-Dimensional Conformal Radiotherapy for Early Glottic Cancer
- The effective application of dynamic arc radiotherapy
- Clinical Outcomes of Volume-Modulated Arc Therapy in 205 Patients with Nasopharyngeal Carcinoma: An Analysis of Survival and Treatment Toxicities
- PO-0982: The impact of plan complexity on the accuracy of VMAT for the treatment of head and neck cancer
- Dosimetric benefits of IMRT and VMAT in the treatment of middle thoracic esophageal cancer: is the conformal radiotherapy still an alternative option?
- Potential advantages of volumetric arc therapy in head and neck cancer
- The impact of continuously‐variable dose rate VMAT on beam stability, MLC positioning, and overall plan dosimetry
- Beyond the DVH--Spatial and biological radiotherapy treatment planning
- Efficiency of biological versus physical optimization for single‐arc VMAT for prostate and head and neck cases
- CRT combined with a sequential VMAT boost in the treatment of upper thoracic esophageal cancer
- Evaluation of the sensitivity of two 3D diode array dosimetry systems to setup error for quality assurance (QA) of volumetric‐modulated arc therapy (VMAT)
- Comparative analysis of SmartArc‐based dual arc volumetric‐modulated arc radiotherapy (VMAT) versus intensity‐modulated radiotherapy (IMRT) for nasopharyngeal carcinoma
- Impact of MLC leaf width on volumetric‐modulated arc therapy planning for head and neck cancers
- Resected gastric cancer with D2 dissection: advances in adjuvant chemoradiotherapy and radiotherapy techniques
Related papers
- 3D treatment planning system-Pinnacle system.
- Application of holographic display in radiotherapy treatment planning II: a multi‐institutional study
- SU-E-T-439: First Experience of Three Dimensional Conformai Radiotherapy (3DCRT) Planning with Helical Tomotherapy.
- SU-F-T-440: The Feasibility Research of Checking Cervical Cancer IMRT Pre- Treatment Dose Verification by Automated Treatment Planning Verification System.
- SU-E-J-254: Utility of Pinnacle Dynamic Planning Module Utilizing Deformable Image Registration in Adaptive Radiotherapy.
- Migration of treatment planning system using existing commissioned planning system
- A VMAT PLANNING SOLUTION FOR NECK CANCER PATIENTS USING THE PINNACLE 3 PLANNING SYSTEM
- Navigating Through and Around the Field Size Limitation on Varian Linear Accelerators When Planning Large IMRT Cases Using the Philips Pinnacle Treatment Planning System
- VMAT to arclet plan conversion in a treatment planning system
- Implement a knowledge‐based automated dose volume histogram prediction module in Pinnacle3 treatment planning system for plan quality assurance and guidance