Comparison of Methods for Blood Glucose Monitoring
Explore this paper's citation graph
Summary
There was a general trend toward greater absolute and percentage deviation with higher plasma glucose values, Nevertheless, for clinical purposes, accuracy is sufficient to permit use of any of the methods tested.
- Type
- article
- Published
- 1981-05-01
- Cited by
- 67
- References
- 7
- OpenAlex
- https://openalex.org/W1980357531
- Semantic Scholar
- https://api.semanticscholar.org/CorpusID:35492309
Keywords
Medicine, Diabetes mellitus, Plasma glucose, Standard deviation, Reference values
References
- Algorithms for Adjustment of Insulin Dosage by Patients Who Monitor Blood Glucose
- Patient self-monitoring of blood glucose and refinements of conventional insulin treatment.
- HOME MONITORING OF BLOOD-GLUCOSE
- Feasibility of Improved Blood Glucose Control in Patients With Insulin-Dependent Diabetes Mellitus
- Jet Injection of Insulin During Self-Monitoring of Blood Glucose
- Home Blood Glucose Monitoring As an Aid in Diabetes Management
- Symposium on home blood glucose monitoring.
Cited by
- Screening for gestational diabetes mellitus. Use and accuracy of capillary blood glucose measured with a reflectance meter.
- Home blood glucose monitoring: keystone for modern diabetes care.
- Accuracy of blood glucose concentrations determined by four visually read reagent strips
- In-hospital bedside blood glucose monitoring: the importance of a quality control program.
- Self-monitoring of blood glucose.
- Precision and costs of techniques for self-monitoring of serum glucose levels.
- Comparison of Five Glucose Meters for Self-Monitoring of Blood Glucose by Diabetic Patients
- Comparison of Visidex and Chemstrip bG with Beckman Glucose Analyzer Determination of Blood Glucose
- Self Blood Glucose Monitoring: An Update
- Self-Monitoring of Blood Glucose in Pregnancy: Past to Present
- Insulin: Its Use in Patients on Peritoneal Dialysis
- Quality Control for Glucose Monitoring Programs
- The clinical information value of the glycosylated hemoglobin assay.
- Assessment of a New Blood Glucose Strip: Comparison of Visidex, Visidex II, and Chemstrip bG with Glucose Analyzer Determination of Blood Glucose
- Capillary blood glucose screening for gestational diabetes: a preliminary investigation.
- Evaluating Clinical Accuracy of Systems for Self-Monitoring of Blood Glucose
- Accuracy in Estimating Fasting Blood Glucose Levels by Patients with Diabetes
- Reagent Strip Glucose Monitoring Methods in Chronic Hemodialysis
- Assessment of visidex II: A new blood glucose monitoring system
- Comparison of Capillary Accu-Chek Blood Glucose Values to Laboratory Values
Related papers
- Order Statistics of Mean and Variance for Climatic Data
- Diabetes Mellitus: Once More About Diagnostics
- Introduction to biostatistics: Part 2, Descriptive statistics.
- Evaluation of Fasting Plasma Glucose as a Screening for Diabetes Mellitus in Middle-aged Adults of Naju Country
- A Study of Newly Detected Diabetes Mellitus Patients among Population of Rural Field Practice Area of A Tertiary Care Centre In Maharashtra