Long-term results of hybrid alumina-on-alumina total hip arthroplasty: 10–14-Year results
Explore this paper's citation graph
- Type
- article
- Published
- 2013-12-01
- Cited by
- 7
- References
- 22
- OpenAlex
- https://openalex.org/W1969900205
- Semantic Scholar
- https://api.semanticscholar.org/CorpusID:136395425
Keywords
Medicine, Survivorship curve, Osteolysis, Harris Hip Score, Surgery
References
- Squeaking in third- and fourth-generation ceramic-on-ceramic total hip arthroplasty: meta-analysis and systematic review.
- Alumina-on-Alumina Total Hip Arthroplasty: A Minimum 18.5-Year Follow-up Study
- Development of ceramic‐on‐ceramic implants for total hip arthroplasty
- Cementless metaphyseal fitting anatomic total hip arthroplasty with a ceramic-on-ceramic bearing in patients thirty years of age or younger.
- Modern Ceramic-on-Ceramic Total Hip Systems in the United States: Early Results
- Ceramic-on-ceramic Bearing Decreases the Cumulative Long-term Risk of Dislocation
- Reliability of Ceramic Components
- Third-generation alumina-on-alumina ceramic bearings in cementless total hip arthroplasty.
- Ten-year results after cementless THA with a sandwich-type alumina ceramic bearing.
- Long-term results of 32-mm alumina-on-alumina THA for avascular necrosis of the femoral head
- A randomised prospective evaluation of ceramic-on-ceramic and ceramic-on-highly cross-linked polyethylene bearings in the same patients with primary cementless total hip arthroplasty
- Projections of primary and revision hip and knee arthroplasty in the United States from 2005 to 2030.
- Total hip arthroplasty using highly cross-linked polyethylene in patients younger than 50 years with minimum 10-year follow-up.
- 10-year follow-up wear analysis of first-generation highly crosslinked polyethylene in primary total hip arthroplasty.
- Clinical outcome, survival and polyethylene wear of an uncemented total hip arthroplasty: a 10- to 12-year follow-up study of 81 hips.
- Ceramic-on-ceramic total hip arthroplasty in patients younger than 20 years.
- Modern total hip arthroplasty in patients younger than 21 years.
- Ten-Year Follow-Up of Patients Younger Than 50 Years With Modern Ceramic-on-Ceramic Total Hip Arthroplasty
- In vitro comparison of the two hard-hard articulations for total hip replacements
- The operation of the century: total hip replacement.
Cited by
- Bearing Surfaces for Total Hip Arthroplasty.
- Design and Simulation of Hip Prosthesis using Finite Elements Methods to fulfill Essential Range of Motion
- Long-term results of alumina ceramic-on-ceramic bearings in cementless total hip arthroplasty: a 20-year minimum follow-up.
- Long-Term Outcomes of Third-Generation Ceramic-on-Ceramic Bearings in Cementless Primary Total Hip Arthroplasty: A 25-Year Survival Analysis.
- The Current Concepts of Total Hip Arthroplasty
- Metallic nanosystems in hard tissue implants
- Perspective and Trends on Bioceramics in Joint Replacement
Related papers
- Minimum 10 year survivorship analysis of a partially coated hydroxyapatite tapered femoral stem in elderly patients with an average age over 75.
- Total hip arthroplasty after acetabular fracture: incidence of complications, reoperation rates and functional outcomes: evidence today.
- The ScanHip ® total hip arthroplasty: Radiographic assessment of 72 hips after 10 years
- The Ideal Total Hip Replacement Bearing Surface in the Young Patient: A Prospective Randomized Trial Comparing Alumina Ceramic-On-Ceramic With Ceramic-On-Conventional Polyethylene: 15-Year Follow-Up.
- A randomised prospective evaluation of ceramic-on-ceramic and ceramic-on-highly cross-linked polyethylene bearings in the same patients with primary cementless total hip arthroplasty
- Uncemented total hip arthroplasty using alumina ceramic bearings at a minimum of 14 years of follow-up
- Pure alumina bearings with cementless stems versus sandwich bearings with cemented stems in total hip arthroplasty.
- Clinical Outcomes and Bearing-Specific Complications Following Fourth-Generation Alumina Ceramic-on-Ceramic Total Hip Arthroplasty: A Single-Surgeon Series of 749 Hips at a Minimum of 5-Year Follow-Up.