Auscultatory blood pressure measurement--effect of pressure on the head of the stethoscope.

Explore this paper's citation graph

Summary

Excessive pressure on the stethoscope head in auscultatory blood pressure measurement does not affect systolic blood pressure value but it does erroneously lower diastolic readings and frequently causes the sounds to persist to zero.

Type
article
Published
1984-08-01
Cited by
27
References
5
Access
Open access

Keywords

Stethoscope, Blood pressure, Medicine, Cardiology, Head (geology)