Finite Element Simulations of Biphasic Articular Cartilages With Localized Metal Implants
Explore this paper's citation graph
Summary
A model to investigate the in vivo time-dependent behavior of the tibiofemoral cartilages surrounding the metal implant, when the joint is subjected to an axial load for various defect sizes shows that time- dependent effects on cartilage behavior are significant, and can be simulated.
- Type
- article
- Published
- 2010-01-01
- Cited by
- 2
- References
- 130
- Access
- Open access
- OpenAlex
- https://openalex.org/W600957995
- Semantic Scholar
- https://api.semanticscholar.org/CorpusID:45668954
Keywords
Implant, Joint (building), Materials science, Cartilage, Poromechanics
References
- Biphasic creep and stress relaxation of articular cartilage in compression? Theory and experiments.
- Drag-induced compression of articular cartilage during a permeation experiment
- Autologous Osteochondral Mosaicplasty for the Treatment of Full-Thickness Defects of Weight-Bearing Joints: Ten Years of Experimental and Clinical Experience
- Articular cartilage: degeneration and osteoarthritis, repair, regeneration, and transplantation.
- Structure and function of articular cartilage and meniscus
- Sheep model in orthopedic research: a literature review.
- Concepts and Applications of Finite Element Analysis
- Telemetric force measurements across the hip after total arthroplasty.
- The permeability of articular cartilage under compressive strain and at high pressures.
- Constitutive modeling of articular cartilage and biomacromolecular solutions.
- A triphasic theory for the swelling and deformation behaviors of articular cartilage.
- Tibiofemoral contact mechanics with a femoral resurfacing prosthesis and a non-functional meniscus.
- Hip osteoarthritis susceptibility is associated with IL1B −511(G>A) and IL1 RN (VNTR) genotypic polymorphisms in Croatian caucasian population
- Tractive forces during rolling motion of the knee: implications for wear in total knee replacement.
- Tensile properties of human knee joint cartilage: I. Influence of ionic conditions, weight bearing, and fibrillation on the tensile modulus
- Loading of the knee joint during activities of daily living measured in vivo in five subjects.
- The effect of porosity and mineral content on the Young's modulus of elasticity of compact bone.
- The forces in the distal femur and the knee during walking and other activities measured by telemetry.
- Osteochondral Defects in the Human Knee
- Hip joint contact forces during stumbling
Cited by
Related papers
- Time-dependent behavior of cartilage surrounding a metal implant for full-thickness cartilage defects of various sizes: a finite element study
- Finite element simulations of a focal knee resurfacing implant applied to localized cartilage defects in a sheep model.
- Implant size and mechanical properties influence the failure of the adhesive bond between cartilage implants and native tissue in a finite element analysis.
- The sensitivity of cartilage contact pressures in the knee joint to the size and shape of an anatomically shaped meniscal implant.
- Osteochondral resurfacing implantation angle is more important than implant material stiffness
- Evaluating the effects of material properties of artificial meniscal implant in the human knee joint using finite element analysis
- Implant stability in different implantation stages: Analysis of various interface conditions
- Stress Analysis of Implant Surrounding Bone: Application of Finite Element Models Which Represent the Implant Displacement under Loading