A comparison of the marginal fit of In-Ceram, IPS Empress, and Procera crowns.
Explore this paper's citation graph
Summary
There were no significant differences among the various stages of the crown fabrication: core fabrication, porcelain veneering, and glazing, but the facial and lingual margins exhibited significantly larger marginal discrepancies than the mesial and distal margins.
- Type
- article
- Published
- 1997-09-01
- Cited by
- 370
- References
- 55
- OpenAlex
- https://openalex.org/W194210959
- Semantic Scholar
- https://api.semanticscholar.org/CorpusID:8140424
Keywords
Procera, Crown (dentistry), Fabrication, Materials science, Glazing
References
- Distortion of ceramometal fixed partial dentures during the firing cycle.
- A new all-ceramic crown. A dense-sintered, high-purity alumina coping with porcelain.
- A clinical evaluation of In-Ceram crowns.
- Slip-casting alumina ceramics for crown and bridge restorations.
- The effect of repeated firings and strength on marginal distortion in two ceramometal systems.
- Measuring fit at the implant prosthodontic interface.
- Porcelain shoulder adaptation using direct refractory dies.
- The estimation of cement film thickness by an in vivo technique
- Oral hygiene in a group of supervised patients with fixed prostheses.
- In vitro comparison of conventional crowns and a new all-ceramic system.
- Scanning electron microscopy of the marginal fit of ceramometal restorations with facially butted porcelain margins.
- An investigation of dental luting cement solubility as a function of the marginal gap.
- Distortion of occlusal porcelain during glazing.
- Comparison of the marginal fit of various ceramic crown systems.
- The effect of repeated firings on the margins of nonprecious ceramometals.
- The accuracy of a high-precision digitizer for CAD/CAM of crowns.
- Effect of in vivo crown margin discrepancies on periodontal health.
- Microleakage--full crowns and the dental pulp.
- Marginal accuracy and geometry of cast titanium copings.
- Marginal distortion of the porcelain- bonded-to-metal complete crown: an SEM study.
Cited by
- In vitro evaluation of the "replica technique" in the measurement of the fit of Procera crowns.
- Effect of ceramic surface treatment on the shear bond strength of a resin cement to different ceramic systems.
- Aesthetic and functional rehabilitation with pressable ceramics.
- Evaluación clínica a tres años de dos sistemas cerámicos en puentes posteriores de cuatro unidades
- Marginal and Internal Crown Fit Evaluation of CAD/CAM versus Press-Laboratory All-Ceramic Crown
- Press-to-zirconia: a case study utilizing cad/cam technology and the wax injection method.
- Anterior discolored teeth restored with procera all-ceramic restorations: a clinical evaluation of the esthetic outcome based on the thickness of the core selected.
- FRACTURE STRENGTH AND MARGINAL FIT OF IN-CERAM, COPY-MILLED IN-CERAM, AND IPS EMPRESS 2 ALL-CERAMIC BRIDGES
- Evaluation of marginal fit of two all-ceramic copings with two finish lines
- Influence of preparation angle on marginal and internal fit of CAD/CAM-fabricated zirconia crown copings.
- Comparison of the fit of Procera crowns made from stone with those made from polyurethane resin.
- Zirconia in dentistry
- Longevity and clinical performance of IPS-Empress ceramic restorations--a literature review.
- Data capture stabilising device for the CEREC Cad/Cam chairside camera
- Avaliação dos tipos de reabilitações fixas dento-suportadas em dentes anteriores
- Marginal adaptation of CAD/CAM zirconia-based crown during fabrication steps
- Evaluation of marginal adaptation of ceramic crowns depending on the marginal design and the addition of ceramic
- Fit of 4-unit FDPs from CoCr and zirconia after conventional and digital impressions
- Zur Verlässlichkeit zirkulärer Randspaltmessungen an vollkeramischen Kronen im Rasterelektronenmikroskop
- EVOLUÇÃO SISTEMAS CERAMICOS
Related papers
- Evaluation of Clinical Effect of Procera Allceram Crown
- Five-year follow-up with Procera all-ceramic crowns.
- Five-year clinical evaluation of Procera AllCeram crowns.
- [Long-term clinical results with Procera AllCeram full-ceramic crowns].
- Prospective clinical 5-year study of ceramic-veneered titanium restorations with the Procera system.
- Retrospective clinical evaluation of 86 Procera AllCeram anterior single crowns on natural and implant-supported abutments.
- Clinical evaluation of 209 all-ceramic single crowns cemented on natural and implant-supported abutments with different luting agents: a 6-year retrospective study.
- Retrievable metal ceramic implant-supported fixed prostheses with milled titanium frameworks and all-ceramic crowns: retrospective clinical study with up to 10 years of follow-up.