Continuous Zoom Calibration by Tracking Salient Points in Endoscopic Video
Explore this paper's citation graph
Summary
The proposed solution for online zoom calibration builds on recent developments in tracking salient points using differential image alignment, is well suited for continuous operation, and makes no assumptions about the camera motion or scene rigidity.
- Type
- article
- Published
- 2014-09-14
- Cited by
- 7
- References
- 14
- Access
- Open access
- OpenAlex
- https://openalex.org/W79756515
- Semantic Scholar
- https://api.semanticscholar.org/CorpusID:6487432
Keywords
Zoom, Computer science, Computer vision, Salient, Artificial intelligence
References
- Multiple View Geometry in Computer Vision
- Laparoscope Self-calibration for Robotic Assisted Minimally Invasive Surgery
- sRD-SIFT: Keypoint Detection and Matching in Images With Radial Distortion
- Automatic Distortion Correction of Endoscopic Images Captured With Wide-Angle Zoom Lens
- Lucas-Kanade 20 Years On: A Unifying Framework
- A minimal solution for relative pose with unknown focal length
- A New Solution for Camera Calibration and Real-Time Image Distortion Correction in Medical Endoscopy–Initial Technical Evaluation
- Scale-Invariant Registration of Monocular Endoscopic Images to CT-Scans for Sinus Surgery
- Simultaneous linear estimation of multiple view geometry and lens distortion
- An efficient solution to the five-point relative pose problem
- Tracking Feature Points in Uncalibrated Images with Radial Distortion
- Multiple View Geometry
- Camera Model and Calibration Procedure for Oblique-Viewing Endoscope
- Multiple view geometry in computer vision (2. ed.)
Cited by
- Stitching and Surface Reconstruction From Endoscopic Image Sequences: A Review of Applications and Methods
- The status of augmented reality in laparoscopic surgery as of 2016
- OmniDRL: Robust Pedestrian Detection using Deep Reinforcement Learning on Omnidirectional Cameras*
- Video-based computer aided arthroscopy for patient specific reconstruction of the Anterior Cruciate Ligament
- OmniDRL: Robust Pedestrian Detection using Omnidirectional Cameras and Deep Reinforcement Learning*
- Automatic localization of endoscope in intraoperative CT image : a simple approach to augmented reality guidance in laparoscopic surgery
Related papers
- Please, Help Me! I Am Lost in Zoom
- Mechanical design of zoom lens and analysis of its focal length
- Camera auto-calibration from a sequence of images
- Non-iterative Camera Calibration Procedure Using A Virtual Camera
- A Novel Camera Calibration Method of Variable Focal Length Based on Single-View
- A Simplified Active Calibration algorithm for Focal Length Estimation
- Algorithm of Camera Focal Length Base on Image