Comparison of right ventricular septal pacing and right ventricular apical pacing in patients receiving cardiac resynchronization therapy defibrillators: the SEPTAL CRT Study
Explore this paper's citation graph
Summary
It is demonstrated that septal RV pacing in CRT is non-inferior to apical RV pacing for LV reverse remodelling at 6 months with no difference in the clinical outcome.
- Type
- article
- Published
- 2015-09-15
- Cited by
- 70
- References
- 39
- Access
- Open access
- OpenAlex
- https://openalex.org/W26374852
- Semantic Scholar
- https://api.semanticscholar.org/CorpusID:4443187
Keywords
Environmental science
References
- Effect of right ventricular lead location on response to cardiac resynchronization therapy in patients with end-stage heart failure.
- Surface electrocardiogram to predict outcome in candidates for cardiac resynchronization therapy: a sub‐analysis of the CARE‐HF trial
- A randomized study of haemodynamic effects and left ventricular dyssynchrony in right ventricular apical vs. high posterior septal pacing in cardiac resynchronization therapy
- A Randomized Study of Defibrillator Lead Implantations in the Right Ventricular Mid‐Septum versus the Apex: The SEPTAL Study τ
- Dual-chamber pacing or ventricular backup pacing in patients with an implantable defibrillator: the Dual Chamber and VVI Implantable Defibrillator (DAVID) Trial.
- Targeted left ventricular lead placement to guide cardiac resynchronization therapy: the TARGET study: a randomized, controlled trial.
- 2010 Focused Update of ESC Guidelines on Device Therapy in Heart Failure
- Comparison of the haemodynamic effects of right ventricular outflow-tract pacing with right ventricular apex pacing: a quantitative review.
- Interlead Distance and Left Ventricular Lead Electrical Delay Predict Reverse Remodeling During Cardiac Resynchronization Therapy
- Longitudinal myocardial strain alteration is associated with left ventricular remodeling in asymptomatic patients with type 2 diabetes mellitus.
- Proposal for a new clinical end point to evaluate the efficacy of drugs and devices in the treatment of chronic heart failure.
- Long-term implications of cumulative right ventricular pacing among patients with an implantable cardioverter-defibrillator.
- Optimal Left Ventricular Lead Position Predicts Reverse Remodeling and Survival After Cardiac Resynchronization Therapy
- Effectiveness of Cardiac Resynchronization Therapy by QRS Morphology in the Multicenter Automatic Defibrillator Implantation Trial–Cardiac Resynchronization Therapy (MADIT-CRT)
- Safety of mid-septal electrode placement in implantable cardioverter defibrillator recipients--results of the SPICE (Septal Positioning of ventricular ICD Electrodes) study.
- Optimization of right ventricular lead position in cardiac resynchronisation therapy ☆
- 2012 EHRA/HRS expert consensus statement on cardiac resynchronization therapy in heart failure: implant and follow-up recommendations and management.
- The effect of cardiac resynchronization on morbidity and mortality in heart failure.
- Impact of the right ventricular lead position on clinical outcome and on the incidence of ventricular tachyarrhythmias in patients with CRT-D.
- The Clinical Implications of Cumulative Right Ventricular Pacing in the Multicenter Automatic Defibrillator Trial II
Cited by
- Resumen de estudios clínicos presentados en el Congreso de 2014 de la Sociedad Europea de Cardiología (30 de agosto-3 de septiembre de 2014, Barcelona, España)
- Summary of the Clinical Studies Reported in the European Society of Cardiology Congress 2014 (August 30 – September 3, 2014, Barcelona, Spain)
- The Role of Cardiovascular Magnetic Resonance in Cardiac Resynchronization Therapy.
- Kardiale implantierbare elektronische Systeme
- Avoiding non-responders to cardiac resynchronization therapy: a practical guide
- Multiple BiV Stimulation Combinations by using Two RV Leads Improve Potential for Response to CRT: Results of the TriV HF ICD Study
- Selection of the Best of 2016 on Cardiac Pacing: Leadless Pacing.
- Selección de lo mejor del año 2016 en terapia de resincronización cardiaca
- Rational and design of EuroCRT: an international observational study on multi-modality imaging and cardiac resynchronization therapy
- Predicting Clinical and Echocardiographic Response After Cardiac Resynchronization Therapy With a Score Combining Clinical, Electrocardiographic, and Echocardiographic Parameters.
- Association between right ventricular lead position and clinical outcomes in patients with cardiac resynchronization therapy
- Association between implantable cardioverter-defibrillator therapy and different lead positions in patients with cardiac resynchronization therapy
- Kardiale implantierbare elektronische Systeme
- Right ventricular lead location, right-left ventricular lead interaction, and long-term outcomes in cardiac resynchronization therapy patients
- Clinical and echocardiographic response of apical vs nonapical right ventricular lead position in CRT: A meta‐analysis
- ICD lead type and RV lead position in CRT-D recipients
- Optimal site selection and image fusion guidance technology to facilitate cardiac resynchronization therapy
- Electrical manipulation of the failing heart
- Long‐Term Outcomes of Cardiac Resynchronization Therapy Using Apical Versus Nonapical Left Ventricular Pacing
- The Role of Cardiovascular Magnetic Resonance in Cardiac Resynchronization Therapy.
Related papers
No related papers recorded.