Low-dose three-dimensional reconstruction of the femur with unit free-form deformation.
Explore this paper's citation graph
Summary
A low-dose method for reconstructing three-dimensional models of femur, using a standard shape model (SSM) and two conventional x-ray images, and once this approach has been validated in vivo, it should be suited to multiple applications of routine clinical and research practices.
- Type
- article
- Published
- 2014-08-01
- Cited by
- 4
- References
- 48
- Access
- Open access
- OpenAlex
- https://openalex.org/W25086542
- Semantic Scholar
- https://api.semanticscholar.org/CorpusID:24082427
Keywords
Urbanity, Terrorism, Compendium, Ideology, Political science
References
- Fit Assessment of Anatomic Plates for the Distal Medial Tibia
- Three-dimensional reconstruction of human femur using consecutive computer tomography images and simulated implantation system
- Evaluation of a new low-dose digital X-ray device: first dosimetric and clinical results in children
- Draw and cut: intuitive 3D osteotomy planning on polygonal bone models
- Radiograph-based femur morphing method
- Validation of subject-specific automated p-FE analysis of the proximal femur.
- Parametric subject-specific model for in vivo 3D reconstruction using bi-planar X-rays: application to the upper femoral extremity
- 3D reconstruction of the proximal femur with low-dose digital stereoradiography
- Reliability of a new method for lower-extremity measurements based on stereoradiographic three-dimensional reconstruction.
- Image processing, geometric modeling and data management for development of a virtual bone surgery system
- Fit optimisation of a distal medial tibia plate
- Iconography : Three-dimensional reconstruction of the rib cage from biplanar radiography
- The Chinese Visible Human (CVH) datasets incorporate technical and imaging advances on earlier digital humans
- A hierarchical statistical modeling approach for the unsupervised 3-D biplanar reconstruction of the scoliotic spine
- Fast global registration of 3D sampled surfaces using a multi-z-buffer technique
- A 2D/3D correspondence building method for reconstruction of a patient-specific 3D bone surface model using point distribution models and calibrated X-ray images
- Active Shape Models-Their Training and Application
- Patient and personnel exposure during CT fluoroscopy-guided interventional procedures.
- Measuring femoral and rotational alignment: EOS system versus computed tomography.
- AN ABJS BEST PAPER: Analysis of Anatomic Periarticular Tibial Plate Fit on Normal Adults
Cited by
- 3D Assessment of Osteosynthesis based on 2D Radiographs
- 2D-to-3D: A Review for Computational 3D Image Reconstruction from X-ray Images
- ASSESSING THE RELATIVE POSITIONING OF AN OSTEOSYNTHESIS PLATE TO THE PATIENT-SPECIFIC FEMORAL SHAPE FROM PLAIN 2D RADIOGRAPHS
- Registration for Orthopaedic Interventions
Related papers
- Boekrecensie: Graham, S. (ed.) (2004) Cities, war and terrorism: towards an urban geopolitics. Oxford: Blackwell.
- Conflict and Terrorism in South Asia Since 9/11
- Terrorism in context
- The Politics of Terrorism
- Understanding global terror
- The historical roots of political violence: revolutionary terrorism in affluent countries
- The Historical Roots of Political Violence. Revolutionary Terrorism in Affluent Countries
- Global Political Geography beyond Geopolitics
- Globalisation and the New Terror: The Asia Pacific Dimension