Improved Eye Plaque Brachytherapy Dosimetry Using Monte Carlo Methods
Explore this paper's citation graph
- Type
- article
- Published
- 2011-07-01
- Cited by
- 2
- References
- 25
- OpenAlex
- https://openalex.org/W20641437
- Semantic Scholar
- https://api.semanticscholar.org/CorpusID:92826084
Keywords
Dosimetry, Brachytherapy, Monte Carlo method, Radiation treatment planning, Collimated light
References
- COMS eye plaque brachytherapy dosimetry simulations for P103d, I125, and C131s.
- Monte Carlo dosimetry for 125I and 103Pd eye plaque brachytherapy with various seed models.
- Effects of gold and silver backings on the dose rate around an 125I seed.
- Brachytherapy dosimetry simulation of eye physics slotted plaque: A Monte Carlo study
- Benchmarking brachydose: Voxel based EGSnrc Monte Carlo calculations of TG-43 dosimetry parameters.
- Monte Carlo dosimetry for 125I and 60Co in eye plaque therapy.
- Update of AAPM Task Group No. 43 Report: A revised AAPM protocol for brachytherapy dose calculations.
- American Brachytherapy Society recommends no change for prostate permanent implant dose prescriptions using iodine-125 or palladium-103.
- Backscatter measurements from a single seed of 125I for ophthalmic plaque dosimetry.
- Dosimetry for 125I seed (model 6711) in eye plaques.
- Design and dosimetric considerations of a modified COMS plaque: the reusable "seed-guide" insert.
- Palladium-103 ophthalmic plaque radiation therapy for choroidal melanoma: 400 treated patients.
- The dosimetry of 125I seed eye plaques.
- Dosimetric accuracy of a deterministic radiation transport based 192Ir brachytherapy treatment planning system. Part I: single sources and bounded homogeneous geometries.
- An approach to using conventional brachytherapy software for clinical treatment planning of complex, Monte Carlo-based brachytherapy dose distributions.
- Dosimetry of interstitial brachytherapy sources: Recommendations of the AAPM Radiation Therapy Committee Task Group No. 43
- The American Brachytherapy Society recommendations for brachytherapy of uveal melanomas.
- A reanalysis of the Collaborative Ocular Melanoma Study Medium Tumor Trial eye plaque dosimetry.
- Dosimetric study of the 15 mm ROPES eye plaque.
- Improved treatment planning for COMS eye plaques.
Cited by
Related papers
- Ruthenium-106 plaque brachytherapy for thick posterior uveal melanomas
- Ruthenium-106 plaque brachytherapy for uveal melanoma: Factors associated with local tumor recurrence
- Brachytherapy for patients with uveal melanoma: historical perspectives and future treatment directions
- Mouse model of brachytherapy in consort with enucleation for treatment of malignant intraocular melanoma.
- Verification of computerized treatment planning for HDR 192Ir brachytherapy for gynaecological cancer.
- Recent developments and best practice in brachytherapy treatment planning.
- Methods for Cf-252 cervix cancer therapy and treatment planning for GYN malignancies in Lexington
- 22 oral Dose parameters for MRI based treatment planning — Analysis of 93 individual fractions in HDR cervix cancer brachytherapy for 22 patients