Total Hip Arthroplasty with Use of the Cementless Zweymüller Alloclassic System: A Ten to Thirteen-Year Follow-up Study
Explore this paper's citation graph
Summary
The Zweymüller Alloclassic prosthesis, particularly its femoral stem, demonstrated good results and durable fixation at a minimum of ten years of follow-up.
- Type
- article
- Published
- 2003-02-01
- Cited by
- 148
- References
- 53
- OpenAlex
- https://openalex.org/W7505887
- Semantic Scholar
- https://api.semanticscholar.org/CorpusID:43498486
Keywords
Medicine, Confidence interval, Radiography, Total hip arthroplasty, Surgery
References
- Morphometric Examination of Straight, Tapered Titanium Stems: A Retrieval Study
- Hip replacement with a threaded acetabular cup. A follow-up study.
- Tissue reactions to titanium endoprostheses. Autopsy studies in four cases.
- Loosening of threaded acetabular components. Radiographic manifestations.
- The uncemented porous-coated anatomic total hip prosthesis. Two-year results of a prospective consecutive series.
- Clinical and radiographic evaluation of total hip replacement. A standard system of terminology for reporting results.
- Grit-blasted titanium femoral stem in cementless primary total hip arthroplasty: a 5- to 10-year multicenter study.
- The prevalence of femoral osteolysis associated with components inserted with or without cement in total hip replacements. A retrospective matched-pair series.
- Acetabular reconstruction with a threaded prosthesis for failed total hip arthroplasty.
- The case for porous-coated hip implants. The femoral side.
- Clinical Experience With Ceramics in Total Hip Replacement
- Comparison of alumina-polyethylene and metal-polyethylene in clinical trials.
- Threaded cup acetabuloplasty. Early clinical experience.
- Comparison of porous-threaded and smooth-threaded acetabular components of identical design. Two- to four-year results.
- Biologic fixation of a press-fit titanium hip joint endoprosthesis.
- Comparison of the results of cemented, porous-ingrowth, and threaded acetabular cup fixation. A meta-analysis of the orthopaedic literature.
- Natural history of femoral focal osteolysis with proximal ingrowth smooth stem implant.
- Wear of the polyethylene acetabular cup. Metallic and ceramic heads compared in a hip simulator.
- Radiographic anatomic structure of the arthritic acetabulum and its influence on total hip arthroplasty.
- Acetabular Screw Rings and Surface Treatment
Cited by
- Good Stability and Minimal Osteolysis with a Biconical Threaded Cup at 10 Years
- Ergebnisse zementfreier Hüftendoprothetik
- Second-generation cementless total hip arthroplasty in patients with osteonecrosis of the femoral head.
- [Cemented total hip arthroplasty in Germany - update 2010].
- Duetto SI stem 周囲骨における骨密度と応力値の算出
- Ten to fifteen-year clinical and radiographic follow-up with a third-generation cementless stem in a young patient population
- Seven to Twelve Year Results with Versys ET Cementless Stem. A Retrospective Study of 225 Cases
- Influence of postoperative treatment, surface treatment and stem design on the outcome of primary total hip arthroplasty
- Long-term follow-up of primary total hip arthroplasty with the Alloclassic Variall system
- Cementless total hip replacement: a prospective clinical study of the early functional and radiological outcomes of three different hip stems
- Cementless stem fixation and primary stability under physiological-like loads in vitro / Zementfreie Schaftverankerung und Primärstabilität unter angenähert physiologischer Belastung in vitro
- The effect of stem alignment on results of total hip arthroplasty with a cementless tapered-wedge femoral component.
- Ceramic Versus Metal Femoral Heads in Combination With Polyethylene Cups Long-Term Wear Analysis at 20 Years
- Excellent long-term survival of an uncemented press-fit stem and screw cup in young patients: Follow-up of 75 hips for 15–18 years
- Pain as symptom of threaded acetabular cup loosening
- Versatile application of short stem during total hip arthroplasty
- Hemiarthroplasty of the hip with and without cement: a randomized clinical trial.
- "Do not implant!"--long-term follow-up of a patient who received a trial hip stem.
- Grit-blasted and hydroxyapatite-coated total hip arthroplasty: an 11- to 14-year follow-up study
- Characterization, quantification, and isolation of aluminum oxide particles on grit blasted titanium aluminum alloy hip implants.
Related papers
- Rigid prosthesis removal following chest wall resection and reconstruction for cancer
- Functional comparison of upper extremity amputees using myoelectric and conventional prostheses.
- Pitfalls of the Rosen anti-incontinence prosthesis.
- Myoelectric prostheses. A long-term follow-up and a study of the use of alternate prostheses.
- A study on the value of the modified KBM prosthesis compared with other types of prosthesis
- Long-term results of VoiceMaster voice prosthesis use in laryngectomized patients.
- [Replacement of a failed total hip prosthesis].
- [Hip prosthesis infection: diagnostic approach and treatment of 27 cases].